UNLOAD Options panel
You use the UNLOAD Options panel to enter information that is used in generating an UNLOAD statement in a utility batch job.
Panel and field definitions
- Allow data changes
- When this option is selected, you must supply a value for the
Isolation Level. The default is selected.
If not selected, FM/Db2 adds the SHRLEVEL REFERENCE clause to the UNLOAD utility control statements, meaning that during the unload operation, rows of the tables can be read, but can not be inserted, updated, nor deleted by other Db2® threads.
- Isolation Level
- This parameter comes into effect when the Allow data changes parameter
is selected. The default is 1 (Cursor stability).
Valid values are:
- 1 (Cursor stability)
- FM/Db2 omits a SHRLEVEL clause to the UNLOAD utility statement. This is equivalent to adding a SHRLEVEL CHANGE ISOLATION CS clause to the UNLOAD utility control statement, meaning that rows can be read, inserted, updated, and deleted from the table space or partition while the data is being unloaded and that the UNLOAD utility reads rows in cursor stability mode.
- 2 (Uncommitted rows)
- FM/Db2 adds a SHRLEVEL CHANGE ISOLATION UR clause to the UNLOAD utility control statement. This means that rows can be read, inserted, updated, and deleted from the table space or partition while the data is being unloaded and that uncommitted rows, if they exist, are unloaded.
- Use IEEE floating point
- When this option is selected, FM/Db2 adds the FLOAT IEEE clause
to the UNLOAD utility control statements.
If not selected, no clause is added; this means that the Db2® UNLOAD utility output format of the numeric floating point numbers are produced in S/390® hexadecimal Floating Point (HFP) format. The default is not selected.
- Allow substitution chars
- When this option is not selected, FM/Db2 adds the NOSUBS
clause to the UNLOAD utility control statement. This means that substitution
characters are not allowed in strings. The substitution character
that is attempted while unloading data is treated as a conversion
error.
The default is selected. A substitution character is sometimes placed in a string when that string is being converted from ASCII to EBCDIC, or converted from one CCSID to another. For example, substitution occurs when a character (sometimes referred to as a code point) that exists in the source CCSID (code page) does not exist in the target CCSID (code page).
- Allow padding
- When this option is selected, the NOPAD clause is not added to
the UNLOAD utility control statements. The default
is selected.
If not selected, FM/Db2 adds the NOPAD clause to the UNLOAD utility control statements.
The Db2® default for UNLOAD processing is to pad variable length columns in the unloaded records to their maximum length, and the unloaded records have the same length for each table. Select the item if you wish to use the Db2® defined default behavior.
When padding is performed:
- The padded data fields are preceded by the length fields that indicate the size of the actual data without the padding.
- When the output records are reloaded using the LOAD utility, padded data fields are treated as varying length data.
- Maximum in Error
- This option specifies the value for the maximum number of records in error that are allowed. The unloading process terminates when this value is reached. FM/Db2 adds a MAXERR clause with specified value to the UNLOAD utility statements. The default value is 1.
- Encoding Scheme
- This option specifies the encoding scheme used by the generated
UNLOAD utility control statement for all output data of the character
type. Valid values are:
- 1 (Preserve encoding scheme)
- The encoding scheme of the source data is preserved (default).
- 2
- EBCDIC is the encoding scheme for all output data of the character type.
- 3
- ASCII is the encoding scheme for all output data of the character type.
- 4
- UNICODE is the encoding scheme for all output data of the character type.
- CCSID Values
- This option specifies the values for the coded character set identifiers (CCSIDs) for the data in the output data sets. If you specify one or more non-zero values for the SBCS data, Mixed DBCS data and DBCS data fields, FM/Db2 adds a CCSID clause to the UNLOAD utility control statements. If all are zero, no CCSID clause is added.
- SBCS data
- Specifies the CCSID value for single byte character set (SBCS) data in output records, including data unloaded in the external character formats.
- Mixed DBCS data
- Specifies the CCSID value for mixed double byte character set (DBCS) data in output records, including data unloaded in the external character formats.
- DBCS data
- Specifies the CCSID value for DBCS data in output records, including
data unloaded in the external character formats.
Zero is the default value for each of the above three CCSID value fields.
With the example settings shown in the figure, the following clauses are added to any generated UNLOAD:
- SHRLEVEL CHANGE ISOLATION UR
- FLOAT IEEE
- NOSUB
- MAXERR 2
- EBCDIC