Object List Options (1 of 2) panel
You use the FM/Db2 Object List Options (1 of 2) panel to set various options that affect the way in which FM/Db2 operates. These options are saved in your ISPF profile and persist from one FM/Db2 session to the next.
Panel and field definitions
- Show all catalog table columns
- Display of catalog table information includes every available
column, including any columns marked as "unused" or "internal use
only" in the DB2 for z/OS SQL Reference.
This option overrides any settings for the Show "unused" catalog
table columns and Show "internal use only" catalog table columns options.
The default is not selected.
- Show "unused" catalog table columns
- Display of catalog table information includes columns marked as
"unused" in the DB2 for z/OS SQL Reference.
This option can be overridden by selecting the Show all catalog
table columns option.
The default is not selected.
- Show "internal use only" catalog table columns
- Display of catalog table information includes columns marked as
"internal use only" in the DB2 for z/OS SQL Reference. This option can
be overridden by selecting the Show all catalog table columns option.
The default is not selected.
- Use automatic column sizing
- Varying-length (VARCHAR) columns of the catalog table being displayed
may be automatically sized, based on the data stored within the column.
Automatic column sizing determines the longest data value in each
varying column as the data is read from Db2®.
This value is then used to set the display width for the column, prior
to the data being displayed.
The default is selected.
- Use extended column name headings
- Column names for the catalog table being processed are replaced
by longer, more meaningful, column headings.
The default is selected.
- Interpret columns containing codes
- Selected columns in the Db2® catalog
table being processed are expanded, based on the value stored within
the column. This feature typically operates on one-character columns
that contain a code. As an example, the TYPE column in SYSIBM.SYSTABLES
is a one-character code containing A,G,M,T,V, or X. The expanded text
for these codes is "Alias", "Created global temporary table", "Materialized
query table", "Table", "View", and "Auxiliary Table".
This option is useful if you are not familiar with the meanings of the codes in the various Db2® catalog tables. Selecting this option overrides any setting for the Use extended column name headings option, and sets that option on.
The default is selected.
- Modify order of columns displayed
- Columns in the Db2® catalog
table may be re-ordered from the order as defined in the Db2® catalog. In addition certain columns may
be marked as held. This feature is intended to place the most important
columns from the catalog table on the left of the display, in the
most logical order. These columns are held, and do not move when scrolling
left and right.
The default is selected.
- Row count
- Limits the number of rows fetched from the Db2® catalog. The value entered applies to:
- Object List selection panels displayed by FM/Db2 functions such as the editor, print, copy, import, export, and data create. For more information on object list selection, see Specifying a Db2 object name. Note that FM/Db2 functions such as edit, copy, print, and so on also have a Row count field on the function entry panel. Once an object has been selected, the function entry Row count field acts to control the number of rows processed in the specified Db2® object.
- Object lists displayed by these FM/Db2 functions:
- Object List Utility (3.4).
- Object Privileges Utility (3.5).
- Explain Utilities (4.5).
A value of 0 or ALL specifies no limit; all rows from the relevant catalog tables are fetched and displayed. When you specify 0, FM/Db2 accesses the Db2® catalog using large mode, thereby minimizing storage usage for the list of Db2® objects.
If you experience "insufficient storage" conditions, you can specify a value to limit the number of rows fetched from Db2®. Another way to limit the number of rows fetched in the Object List utility (option 3.4) is to specify selection criteria on the function entry panel.
The default is 1000.
- Display widths, filtering
- Select this option to navigate to the second Object
List Options panel. The default is selected. The Object List
utility displays information in Db2® catalog
tables. Some of the columns within those tables are defined as varying
columns with potentially very long maximum lengths.
You can use the Use automatic column sizing option to reduce the maximum display width for varying columns to the maximum that is needed to display the data for each column.
Additional control can be achieved by specifying minimum and maximum display widths for the various column types shown on the panel. All values are optional. (See Object List Options (2 of 2) panel. A minimum value ensures that the display width is at least the value specified, even if there is no displayable data for the column in all rows processed. Specifying a minimum value does not prevent the display width expanding, if needed, to accommodate longer data.
Parent panels
Child panels
To display this panel… | Use/do this |
---|---|
Object List Options (2 of 2) panel | Press the NxtPage function key (F11) |