Subsystem Settings Menu panel
The Subsystem Settings Menu is displayed when you select option 6 from the Settings Menu.
On this menu, you specify:
- The subsystem settings panel that you require.
- The ID of the IMS subsystem that you want the settings for.
Panel and field definitions
Process Options Help ────────────────────────────────────────────────────────────────────────────── FM/IMS Subsystem Settings Menu DLI mode settings 1 Parameters Parameters passed to the IMS region controller 2 Data sets 1 DFSVSAMP, RESLIB and IMS macros data set names 3 Data sets 2 RECON, ACBLIB and IMS log data set names 4 Options Autosave, checkpoint frequencies and PROCOPTs BMP mode settings 5 Parameters Parameters passed to the IMS region controller 6 Options Autosave, checkpoint frequencies and PROCOPTs DLI and BMP mode settings 7 Data sets 1 PSB and DBD data set names 8 Data sets 2 Template data set names IMS Subsystem Name IF52 Command ===> F1=Help F2=Split F3=Exit F4=CRetriev F7=Backward F8=Forward F9=Swap F10=Actions F12=Cancel
On the Command line, enter:
- 1 for the DLI Mode Parameters panel
- The DLI Mode Parameters panel allows you to view and modify the parameters that are passed to the IMS region controller when a File Manager/IMS function is run in DLI mode.
- 2 for the DLI Mode Data Sets 1 panel
- The DLI Mode Data Sets 1 panel allows you to view and modify the names of the DFSVSAMP, RESLIB, and IMS macros data sets used by the FM/IMS functions when run in DLI mode.
- 3 for the DLI Mode Data Sets 2 panel
- The DLI Mode Data Sets 2 panel allows you to view and modify the names of the RECON, ACBLIB, and IMS log data sets used by the FM/IMS functions when run in DLI mode.
- 4 for the DLI Mode Options panel
- The DLI Mode Options panel allows you to view and modify selected options used by the FM/IMS functions when run in DLI mode.
- 5 for the BMP Mode Parameters panel
- The BMP Mode Parameters panel allows you to view and modify the parameters that are passed to the IMS region controller when a File Manager/IMS function is run in BMP mode.
- 6 for the BMP Mode Options panel
- The BMP Mode Options panel allows you to view and modify selected options used by the FM/IMS functions when run in BMP mode.
- 7 for the PSB and DBD Data Sets panel
- The PSB and DBD Data Sets panel allows you to view and modify the names of the PSB and DBD data sets used by the FM/IMS functions.
- 8 for the Template Data Sets panel
- The Template Data Sets panel allows you to view and modify the names of the Template data sets used by the FM/IMS functions.
- IMS Subsystem Name
- Enter the ID of the IMS subsystem that you want the settings for. If the field is blanked out or a pattern is entered and there are subsystem names in the FM/IMS installation options module that match the pattern, the Subsystem Selection panel is displayed. You can select a subsystem from the list of subsystems displayed on that panel.
Parent panels
Child panels
- None.