Subsystem Selection panel
The Subsystem Selection panel is displayed when you enter
either no subsystem name or a subsystem name pattern on these panels:
- Browse Entry panel
- Edit Entry panel
- Delete/Define Entry panel
- Initialize Entry panel
- Extract Entry panel
- Load Entry panel
- Print Entry panel
- Batch Edit Entry panel
- Batch Browse Entry panel
- Subsystem Settings Menu panel
If no subsystem name is supplied, all IMS subsystems specified in the FM/IMS installation options module are shown on the panel. If a subsystem name pattern is supplied, all IMS subsystems specified in the FM/IMS installation options module that have a name matching the pattern are shown on the panel.
Panel and field definitions
- Cmd
- Selection entry field.
To select a subsystem, enter
S
in the Cmd field and press Enter. You can only select a subsystem for:- Edit, Delete/Define, Initialize, Load and Batch Edit when the subsystem has not been defined as read only.
- A function that runs in BMP mode when the subsystem is active and has not been defined as DLI mode only.
- A function that runs in DLI mode when the subsystem has not been defined as BMP mode only.
- A function that uses a dynamic PSB when the subsystem has not been defined as static PSB only.
- A function that uses a static PSB when the subsystem has not been defined as dynamic PSB only.
- The BMP mode settings panels when the subsystem has not been defined as DLI mode only.
- The DLI mode settings panels when the subsystem has not been defined as BMP
mode only.
Note: The Cmd field is protected when you are not allowed to select the subsystem.
- SSID
- The IMS subsystem ID. The subsystem ID is highlighted when when you are allowed to select the subsystem.
- Status
- The current status of the subsystem. The subsystem can be ACTIVE or INACTIVE.
- IMS VER
- The version of IMS that the subsystem runs. The version number is only displayed when the current status of the subsystem is active.
- Read Only
- Whether or not the subsystem has been defined as read only in the
FM/IMS installation options module (Y or N respectively). FM/IMS prevents you
from selecting a read only subsystem for Edit, Delete/Define, Initialize,
Load and Batch Edit.
Note: A subsystem can be defined as read only for one region type (DLI or BMP) and not read only for the other.
- PSB Types
- The PSB types that you can use to access databases in the
subsystem:
- BOTH
- You can use both dynamic and static PSBs.
- STAT
- You can only use static PSBs.
- DYN
- You can only use dynamic PSBs.
FM/IMS prevents you from selecting:- A static PSB only subsystem for a function that uses a dynamic PSB.
- A dynamic PSB only subsystem for a function that uses a static PSB.
The PSB types you can use to access a subsystem in BMP mode may be different from the PSB types you can use to access the subsystem in DLI mode.
- Region Types
- The region types you can use to access databases in the
subsystem:
- BOTH
- You can use both BMP and DLI regions.
- BMP
- You can only use BMP regions.
- DLI
- You can only use DLI regions.
FM/IMS prevents you from selecting:- A BMP mode only subsystem for a function that runs in DLI mode.
- A BMP mode only subsystem for a DLI mode settings panel.
- A DLI mode only subsystem for a function that runs in BMP mode.
- A DLI mode only subsystem for a BMP mode settings panel.
- AGNs Used
- Whether or not the subsystem uses AGNs to secure dependent regions (Y or N respectively).
- Description
- The subsystem description as specified in the FM/IMS installation options module.
Use the REFRESH primary command to refresh the statuses of the listed subsystems.