DWW0169E
Data set dddd is restored from a backup-while-open copy but the extracted recovery point time of vvvv from the ICF catalog cannot be used.
CICS® VR determined that data set dddd is restored from a backup-while-open copy, but its recovery point time vvvv in the ICF catalog is either damaged or in the incorrect format. The correct format in the ICF catalog should be an 8-byte field split into 2 packed-decimal fields, each 4-bytes long, in the format yyyydddF, and hhmmssF, where yyyy, ddd, hh, mm, and ss represent date and time components.
If no STARTTIME keyword is provided, processing of CICS® VR stops and recovery does not occur.
- Batch–Supply a STARTTIME keyword that overrides the unusable recovery point time, ensuring that recovery begins at a time before, or equal to, the actual recovery point time. If the true recovery point time cannot be determined, specify a STARTTIME value of 86001, which causes all records from the logs to be applied.
- Online–Provide a valid STARTTIME in the VSAM sphere parameters secondary window.