DWW0639E
ESDS write-add XRBA from CICS® TS log record is not equal to actual XRBA used. Data set name is dddd. Logged XRBA is cccccccc. Actual XRBA is dddddddd. Record appended to data set.
CICS® VR has added a record to the ESDS data set dddd that originated from a CICS® TS log, but the XRBA used on the VSAM file does not correspond with the XRBA specified on the log record. When CICS® TS adds a record to an ESDS data set, the real XRBA used is placed in the log record. Because CICS® TS anticipates the RBA before the write operation, it is possible that CICS® TS could miscalculate the XRBA, thus, CICS® VR only carries out this check when recovering from CICS® TS logs.
This message is followed by a message, in the range DWW0210–DWW0212, which shows the system action.
- Batch–If you want to accept this logical inconsistency, provide an error exit so that CICS® VR ignores the error condition.
- Online–If you want to accept this logical inconsistency, provide an error exit so that CICS® VR ignores the error condition.