DWW0134I

Redundant or CICS® VR V1 parameter(s) are found and ignored.

The listed command contains one or more parameters that are unique to CICS® VR Version 1. These parameters are not used by CICS® VR Version 2, or later, so it is ignored:
  • STRNO, parameter of the BLDVRP command. It is always set to 3 in CICS® VR.
  • KEYLEN, parameter of the BLDVRP command. The key length is calculated by CICS® VR.
  • VSAMERROR, parameter of the EXITS command. This exit is not used by CICS® VR.

The parameters are ignored. CICS® VR continues verifying commands. The recovery run still occurs.

  • Batch–Replace the command with a valid command for CICS® VR Version 2, or later, and rerun the job if necessary.
  • Online–Check your changes to the CICS® VR JCL skeleton. Replace the command with a valid command for CICS® VR Version 2, or later, and rerun the job if necessary.