DWW0135S

The ALLOCATE command contains an invalid parameter, or the number of values in the volume and unit parameters are inconsistent.

One of the following occurred:
  • An unrecognized parameter has been submitted in the ALLOCATE command.
  • The VOLUME parameter was coded without the UNIT parameter.
  • The UNIT parameter was coded without the VOLUME parameter.
The number of values supplied in the VOLUME and UNIT parameters must be the same as the number of logs specified in the log parameter.

Processing of this command stops. The remaining commands are processed, but no recovery occurs.

  • Batch–Remove the invalid parameter or ensure that the correct number of UNIT and VOLUME parameters are supplied, and then resubmit the job.
  • Online–Check your changes to the CICS® VR JCL skeleton. Remove the invalid parameter and resubmit the job.