MAX_IFRM_RCVD
| Required? | No |
| Keyword Type | Unsigned number |
| Range | 0–127 |
| Multiples Allowed? | No, only one for each LINK_STATION keyword |
MAX_IFRM_RCVD = (
@TYPE = UNSIGNEDNUMBERKEYWORD
@RANGE = 0,127
)
The MAX_IFRM_RCVD parameter determines the maximum number of I-frames that can be received by the local link stations before an acknowledgment is sent.
The value is an integer in the range of 0–127 frames.
If MAX_IFRM_RCVD is set to zero, the default value from the PORT keyword is used.
![]() |
For a multipath channel (MPC) DLC, MAX_IFRM_RCVD must be specified as 0. |
This parameter is optional.