CINC Collector is already active for userid
The Command Flow Collector is already active for a user when an attempt to start the
Command Flow collector for the same user is made. If the CIUCNTL control file is shared across the
CICS regions, then only one Command Flow collector can be active for a given user at any given time
in any of the shared regions.
The second collector start request is terminated because only one active collector
is permitted for each user.
Press F7 (Statistics) on the CICS® IA Command
Flow Options panel to find out which regions the Command Flow collector is already running for the
user.
CIUACM60, CIUACM61, CIUAWSCF
Destination
Terminal end
user and CINT TD queue.