TRANSMISSION_FLAGS
| Required? | Yes |
| Keyword Type | Unsigned number |
| Default | 1 |
| Range | 1–10 |
| Multiples Allowed? | No, only one for each PORT_SDLC_SPECIFIC_DATA parameter |
TRANSMISSION_FLAGS = (
@TYPE = UNSIGNEDNUMBERKEYWORD
@RANGE = 1,10
@REQUIRED = 1
@DEFAULT = 1
)
The TRANSMISSION_FLAGS parameter specifies the minimum number of flags inserted to produce idle time between transmitted frames.
Reviewers:
There seems to be a discrepancy between the range listed in the table and the range listed in the details. Is this correct?
A flag is the time it takes to send one byte, and represents a delay between frames. The values are 1, 3, 4, 6, and 10. Change this parameter to a value other than 1 if the device at the other end of the communication link can not receive frames with only one intervening flag.
This parameter is required. The default is 1 flag.