STATION_POLL_COUNT

Required? No
Keyword Type Unsigned number
Default 1
Range 1–10
Multiples Allowed? No, only one for each PORT_SDLC_SPECIFIC_DATA parameter
   STATION_POLL_COUNT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 1,10
      @DEFAULT = 1
    )
 

The STATION_POLL_COUNT parameter specifies the number of times an active station is polled in the context of the polling list before a station from the inactive list is polled.

The value is an integer in the range 1–10 polls.

This parameter is optional. The default is 1 poll.