DWW0701S

Dynamic allocation of data set dddd failed. Return code-R15=cc1, MVS RC=cc2.

Before opening the data set, CICS® VR issued the MVS macro DYNALLOC to dynamically allocate the data set. Allocation failed with the MVS return code cc2. cc1 is the return code in register 15.

CICS® VR stops the recovery and prints the reports.

  • Batch–For an explanation of the MVS return code, see z/OS® MVS Authorized Assembler Services Guide. Look at the codes and correct any errors. Restore the VSAM data sets from the backup copies and resubmit the job.
  • Online–For an explanation of the MVS return code, see z/OS® MVS Authorized Assembler Services Guide. Look at the codes and correct any errors. Restore the VSAM data sets from the backup copies and resubmit the recovery job.