Plan View limit: maximum five users using the same engine
If you try to open the Plan View when five users are already
concurrently using it, with the same engine, your request is rejected
with the following error message: AWSJCO136E No more than
5 users are allowed to perform this operation at the same time. The
maximum number of concurrent requests has been reached: please try
again later.
Cause and solution:
The maximum number of users that can use the Plan View connected to the same engine is five.
If needed, you can modify this limit by editing the com.ibm.tws.conn.plan.view.maxusers property in the TWSConfig.properties file.