TWO_WAY_SVC_COUNT
| Required? | No |
| Keyword Type | Unsigned number |
| Default | 0 |
| Range | 0–60000 |
| Multiples Allowed? | No, only one for each PORT_X25_SPECIFIC_DATA parameter |
TWO_WAY_SVC_COUNT = (
@TYPE = UNSIGNEDNUMBERKEYWORD
@RANGE = 0,60000
@DEFAULT = 0
)
The TWO_WAY_SVC_COUNT parameter specifies how many two-way SVCs can be used by this link for incoming calls or by the data terminal equipment (DTE) for outgoing calls. The value that you type in this field is the one provided by the network supplier when you subscribed to the network.
The value is an integer in the range 0–60000.
This parameter is optional. The default is 0.
Note:
The total number of virtual circuits for each link can not
exceed 1 024, unless the CCITT compliance is specified as 1988. In this case,
the total number can be 4 095. This number includes both permanent virtual
circuits (PVCs) and SVCs.