PORT_X25_SPECIFIC_DATA

Required? No
Keyword Type Complex
Multiples Allowed? Yes
PORT_X25_SPECIFIC_DATA = (
   ACCEPT_INCOMING_CALLS = (
      @TYPE = BOOLEANKEYWORD
      @DEFAULT = NO
    )
   ALTERNATE_REMOTE_PHONE_NUMBER = (
      @TYPE = STRINGKEYWORD
      @FIELD_LENGTH = 1,64
    )
   COMPLIANCE = (
      @TYPE = ENUMKEYWORD
        @ENUM_LIST = (
         1980_COMPLIANCE = 1980
         1984_COMPLIANCE = 1984
         1988_COMPLIANCE = 1988
      )
      @DEFAULT = 1984_COMPLIANCE
    )
   DEFAULT_WINDOW_SIZE = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 1,127
      @DEFAULT = 2
    )
   DIAL_TYPE = (
      @TYPE = ENUMKEYWORD
        @ENUM_LIST = (
         PULSE = 80
         TONE = 84
      )
      @DEFAULT = TONE
    )
   FRAME_INACTIVITY_TIMEOUT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,255
      @DEFAULT = 30
    )
   FRAME_RETRANSMISSION_TIMEOUT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 1,60
      @DEFAULT = 3
    )
   FRAME_SEQUENCE = (
      @TYPE = ENUMKEYWORD
        @ENUM_LIST = (
         MODULO_8 = 8
         MODULO_128 = 128
      )
      @DEFAULT = MODULO_8
    )
   FRAME_TRANSMISSION_RETRY_COUNT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 1,255
      @DEFAULT = 20
    )
   FRAME_WINDOW_SIZE = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 1,127
      @DEFAULT = 7
    )
 
   INSERT_CALLING_ADDRESS = (
      @TYPE = BOOLEANKEYWORD
    )
   IN_ONLY_SVC_COUNT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   IN_ONLY_SVC_START = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   LOCAL_DTE_ADDRESS = (
      @TYPE = STRINGKEYWORD
      @FIELD_LENGTH = 1,15
    )
   MAX_PIU_SIZE = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 265,4115
      @DEFAULT = 2048
    )
   MODEM_NAME = (
      @TYPE = STRINGKEYWORD
      @FIELD_LENGTH = 1,256
    )
   NETWORK_CONNECTION_TYPE = (
      @TYPE = ENUMKEYWORD
        @ENUM_LIST = (
         LEASED = 0
         SWITCHED = 1
      )
      @DEFAULT = SWITCHED
    )
   OUT_ONLY_SVC_COUNT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   OUT_ONLY_SVC_START = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   PACKET_SIZE = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 16,4096
      @DEFAULT = 128
    )
   PORT_SPEED = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 2400,115200
      @DEFAULT = 57600
    )
   PVC_COUNT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   PVC_START = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   REMOTE_PHONE_NUMBER = (
      @TYPE = STRINGKEYWORD
      @FIELD_LENGTH = 1,64
    )
   SEQUENCING = (
      @TYPE = ENUMKEYWORD
        @ENUM_LIST = (
         MODULO_8 = 8
         MODULO_128 = 128
      )
      @DEFAULT = MODULO_8
    )
   SHARED_RAM_ADDRESS = (
      @TYPE = HEXNUMBERKEYWORD
      @RANGE = C0000,FC000
    )
   TRANSMISSION_FLAGS = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 1,10
      @DEFAULT = 1
    )
   TWO_WAY_SVC_COUNT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   TWO_WAY_SVC_START = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 0,60000
      @DEFAULT = 0
    )
   USE_CONSTANT_RTS = (
      @TYPE = BOOLEANKEYWORD
      @DEFAULT = 1
    )
   USE_NRZI_ENCODING = (
      @TYPE = BOOLEANKEYWORD
      @DEFAULT = 0
    )
   USE_X32_PROTOCOL = (
      @TYPE = BOOLEANKEYWORD
      @DEFAULT = 0
    )
   X32_IDENTITY = (
      @TYPE = HEXSTRINGKEYWORD
      @FIELD_LENGTH = 1,32
    )
   X32_SIGNATURE = (
      @TYPE = HEXSTRINGKEYWORD
      @FIELD_LENGTH = 1,32
    )
INCOMING_CALL_FILTER = (
 @MERGE_SIMPLE_KEYWORDS = 0
 
   ACCEPT_CHARGES = (
      @TYPE = BOOLEANKEYWORD
      @DEFAULT = 0
    )
   DTE_ADDRESS = (
      @TYPE = STRINGKEYWORD
      @FIELD_LENGTH = 0,16
    )
   DTE_ADDRESS_EXTENSION = (
      @TYPE = STRINGKEYWORD
      @FIELD_LENGTH = 0,8
    )
 
)
*The end of Complex Keyword INCOMING_CALL_FILTER
 
   DUMB_CARD_INTERFACE = (
      @TYPE = BOOLEANKEYWORD
      @REQUIRED = 1
      @DEFAULT = 0
    )
 
   OEM_PORT_DATA = (
      @MERGE_SIMPLE_KEYWORDS = 0
 
     OEM_DATA = (
       @TYPE = HEXSTRINGKEYWORD
     )
   )
)
 
*The end of Complex Keyword PORT_X25_SPECIFIC_DATA
The PORT_X25_SPECIFIC_DATA parameter is a complex keyword comprised of the following parameter keywords:
  • ACCEPT_CHARGES
  • ACCEPT_INCOMING_CALLS
  • ALTERNATE_REMOTE_PHONE_NUMBER
  • COMPLIANCE
  • DEFAULT_WINDOW_SIZE
  • DIAL_TYPE
  • DTE_ADDRESS
  • DTE_ADDRESS_EXTENSION
  • DUMB_CARD_INTERFACE
  • FRAME_INACTIVITY_TIMEOUT
  • FRAME_RETRANSMISSION_TIMEOUT
  • FRAME_SEQUENCE
  • FRAME_TRANSMISSION_RETRY_COUNT
  • FRAME_WINDOW_SIZE
  • INCOMING_CALL_FILTER
  • INSERT_CALLING_ADDRESS
  • IN_ONLY_SVC_COUNT
  • IN_ONLY_SVC_START
  • LOCAL_DTE_ADDRESS
  • MAX_PIU_SIZE
  • MODEM_NAME
  • NETWORK_CONNECTION_TYPE
  • OEM_PORT_DATA
  • OUT_ONLY_SVC_COUNT
  • OUT_ONLY_SVC_START
  • PACKET_SIZE
  • PORT_SPEED
  • PVC_COUNT
  • PVC_START
  • REMOTE_PHONE_NUMBER
  • SEQUENCING
  • SHARED_RAM_ADDRESS
  • TRANSMISSION_FLAGS
  • TWO_WAY_SVC_COUNT
  • TWO_WAY_SVC_START
  • USE_CONSTANT_RTS
  • USE_NRZI_ENCODING
  • USE_X32_PROTOCOL
  • X32_IDENTITY
  • X32_SIGNATURE

See the descriptions of the parameter keywords to define the PORT_X25_SPECIFIC_DATA parameter.