PSBLIBn


1 PSBLIB1=
2.1! IMS.PSBLIB
2.1 dsname

1 PSBLIBn=dsname
PSBLIBn
Where n is a number in the range 1 to 6, specifies the names of the load libraries that contain the program specification blocks (PSBs) that FM/IMS and IMS are to use.

The specified data sets are used when the ACBs are managed by your installation (ACBMGMT=ACBLIB).

These parameters are optional. But if you specify a PSBLIB parameter, you must also specify the PSBLIB parameters that precede it. So, for example, if you specify the PSBLIB3 parameter, you must also specify the PSBLIB1 parameter and the PSBLIB2 parameter.

If no PSBLIB parameters are specified on the FMN1POPI macro statement, FM/IMS uses either the PSBLIB values on the FMN1POPD macro statement (if specified), or IMS.PSBLIB.

If you do not want the user to override the values you specify for these parameters, set UPSBLIB=N.

Note: When IMS management of ACBs is enabled (ACBMGMT=CATALOG), these parameters are not used, as FM/IMS and IMS get the PSBs from the IMS catalog that the subsystem uses.