EPC - End Processing user exit parameter list
Offsets | Type | Access | Len | Name and description | |
---|---|---|---|---|---|
Dec | Hex | ||||
0 | (0) | CHAR | R/O | 4 | VERSION Parameter list version (currently 0002). |
4 | (4) | CHAR | R/O | 4 | (Reserved) |
8 | (8) | CHAR | R/W | 1 | IS_DUPLICATE
This is a duplicate fault (Y/N). |
9 | (9) | CHAR | R/W | 1 | SUPPRESS_MINIDUMP
Suppress minidump (Y/N). This flag is set by Fault Analyzer based on the MaxMinidumpPages option setting and the expected minidump pages for this fault. It can be overridden by an End Processing user exit. |
10 | (A) | CHAR | R/O | 1 | (Reserved) |
11 | (B) | CHAR | R/W | 1 | SUPPRESS_FAULT_ENTRY If real-time, suppress history file fault entry, or if fault entry refresh, do not update the history file fault entry (Y/N). |
12 | (C) | CHAR | R/O | 15 | (Reserved) |
26 | (1A) | CHAR | R/O | 5 | MINUTES_SINCE_LAST_DUP Number of minutes
elapsed since recording of last duplicate fault (nnnnn). If blank,
no duplicate fault was found. Note: The maximum value of 99999 is
used whenever the number of minutes exceeds the limit of this field. |
31 | (1F) | CHAR | R/O | 1 | ANALYSIS_SUCCESSFUL
Successful analysis (Y/N). The criteria for
successful analysis are the following:
|
32 | (20) | CHAR | R/O | 88 | (Reserved) |
120 | (78) | CHAR | R/W | 1 | SUPPRESS_DUMP Suppress dump (Y/N). This flag affects the suppression of the MVS™ system dump or CICS® transaction dump. For details, see Dump suppression. |
121 | (79) | CHAR | R/O | 63 | (Reserved) |