DOWNSTREAM_LU_INDICATION
![]() |
This verb applies only to Communications Server. |
VCB Structure
typedef struct downstream_lu_indication
{
unsigned short opcode; /* verb operation code */
unsigned char attributes; /* attributes */
unsigned char format; /* format */
unsigned short primary_rc; /* primary return code */
unsigned long secondary_rc; /* secondary return code */
unsigned char data_lost; /* previous indication lost */
unsigned char dspu_name[8]; /* PU Name */
unsigned char ls_name[8]; /* Link station name */
unsigned char dslu_name[8]; /* LU Name */
unsigned char description[RD_LEN]; /* resource description */
unsigned char nau_address; /* NAU address */
unsigned char lu_sscp_sess_active;
/* Is SSCP session active? */
unsigned char plu_sess_active; /* Is PLU-SLU session active? */
unsigned char dspu_services; /* DSPU services */
unsigned char reserv1; /* reserved */
SESSION_STATS lu_sscp_stats; /* LU-SSCP session statistics */
SESSION_STATS ds_plu_stats; /* Downstream PLU-SLU sess stats */
SESSION_STATS us_plu_stats; /* Upstream PLU-SLU sess stats */
} DOWNSTREAM_LU_INDICATION;typedef struct session_stats
{
unsigned short rcv_ru_size; /* session receive RU size */
unsigned short send_ru_size; /* session send RU size */
unsigned short max_send_btu_size; /* max send BTU size */
unsigned short max_rcv_btu_size; /* max rcv BTU size */
unsigned short max_send_pac_win; /* max send pacing window size */
unsigned short cur_send_pac_win; /* curr send pacing window size */
unsigned short max_rcv_pac_win; /* max rcv pacing window size */
unsigned short cur_rcv_pac_win; /* curr receive pacing win size */
unsigned long send_data_frames; /* number of data frames sent */
unsigned long send_fmd_data_frames;
/* num FMD data frames sent */
unsigned long send_data_bytes; /* number of data bytes sent */
unsigned long rcv_data_frames; /* num of data frames received */
unsigned long rcv_fmd_data_frames;
/* num FMD data frames received */
unsigned long rcv_data_bytes; /* num data bytes received */
unsigned char sidh; /* session ID high byte */
unsigned char sidl; /* session ID low byte */
unsigned char odai; /* ODAI bit set */
unsigned char ls_name[8]; /* Link station name */
unsigned char pacing_type; /* type of pacing in use */
} SESSION_STATS;Parameters
- opcode
- AP_DOWNSTREAM_LU_INDICATION
- attributes
- The attributes of the verb. This field is a bit field. The first bit
contains the visibility of the resource to be defined and corresponds to one
of the following:
AP_EXTERNALLY_VISIBLE
AP_INTERNALLY_VISIBLE - format
- Identifies the format of the VCB. This field is set to zero to specify the version of the VCB listed above.
- primary_rc
- AP_OK
- secondary_rc
- Equals zero.
- data_lost
- Specifies whether data has been lost (AP_YES or AP_NO). It is set when an internal component detects a failure that has caused a previous indication to be lost. If the data_lost flag is set to AP_YES then subsequent data fields can be set to null. The application should issue a QUERY verb to update the information that has been lost.
- dspu_name
- Name of the downstream PU associated with the downstream LU. This is an 8-byte alphanumeric type-A EBCDIC string (starting with a letter), padded to the right with EBCDIC spaces.
- ls_name
- Name of link station. This is an 8-byte string in a locally displayable character set. All 8 bytes are significant and must be set.
- dslu_name
- Name of the downstream LU. This is an 8-byte alphanumeric type-A EBCDIC string (starting with a letter), padded to the right with EBCDIC spaces.
- description
- Resource description (as specified on DEFINE_DOWNSTREAM_LU).
- nau_address
- Network addressable unit address of the LU which must be in the range 1–255.
- lu_sscp_sess_active
- Indicates whether the LU-SSCP session to the downstream LU is active. Set to either AP_YES or AP_NO.
- plu_sess_active
- Indicates whether the PLU-SLU session to the downstream LU is active. Set to either AP_YES or AP_NO.
- dspu_services
- Specifies the services which the local node provides to the downstream
LU across the link. This is set to one of the following.
- AP_PU_CONCENTRATION
- Local node provides PU concentration for the downstream PU.
- AP_DLUR
- Local node provides DLUR support for the downstream PU.
- lu_sscp_stats.rcv_ru_size
- This field is always reserved.
- lu_sscp_stats.send_ru_size
- This field is always reserved.
- lu_sscp_stats.max_send_btu_size
- Maximum BTU size that can be sent.
- lu_sscp_stats.max_rcv_btu_size
- Maximum BTU size that can be received.
- lu_sscp_stats.max_send_pac_win
- This field will always be set to zero.
- lu_sscp_stats.cur_send_pac_win
- This field will always be set to zero.
- lu_sscp_stats.max_rcv_pac_win
- This field will always be set to zero.
- lu_sscp_stats.cur_rcv_pac_win
- This field will always be set to zero.
- lu_sscp_stats.send_data_frames
- Number of normal flow data frames sent.
- lu_sscp_stats.send_fmd_data_frames
- Number of normal flow FMD data frames sent.
- lu_sscp_stats.send_data_bytes
- Number of normal flow data bytes sent.
- lu_sscp_stats.rcv_data_frames
- Number of normal flow data frames received.
- lu_sscp_stats.rcv_fmd_data_frames
- Number of normal flow FMD data frames received.
- lu_sscp_stats.rcv_data_bytes
- Number of normal flow data bytes received.
- lu_sscp_stats.sidh
- Session ID high byte.
- lu_sscp_stats.sidl
- Session ID low byte.
- lu_sscp_stats.odai
- Origin destination address indicator. When bringing up a session, the sender of the BIND sets this field to zero if the local node contains the primary link station, and sets it to 1 if the BIND sender is the node containing the secondary link station.
- lu_sscp_stats.ls_name
- Link station name associated with statistics. This is an 8-byte string in a locally displayable character set. All 8 bytes are significant.
- lu_sscp_stats.pacing_type
- Receive pacing type in use on the upstream LU-SSCP session. This will take the value AP_NONE.
- ds_plu_stats.rcv_ru_size
- Maximum receive RU size.
- ds_plu_stats.send_ru_size
- Maximum send RU size.
- ds_plu_stats.max_send_btu_size
- Maximum BTU size that can be sent.
- ds_plu_stats.max_rcv_btu_size
- Maximum BTU size that can be received.
- ds_plu_stats.max_send_pac_win
- Maximum size of the send pacing window on this session.
- ds_plu_stats.cur_send_pac_win
- Current size of the send pacing window on this session
- ds_plu_stats.max_rcv_pac_win
- Maximum size of the receive pacing window on this session.
- ds_plu_stats.cur_rcv_pac_win
- Current size of the receive pacing window on this session.
- ds_plu_stats.send_data_frames
- Number of normal flow data frames sent.
- ds_plu_stats.send_fmd_data_frames
- Number of normal flow FMD data frames sent.
- ds_plu_stats.send_data_bytes
- Number of normal flow data bytes sent.
- ds_plu_stats.rcv_data_frames
- Number of normal flow data frames received.
- ds_plu_stats.rcv_fmd_data_frames
- Number of normal flow FMD data frames received.
- ds_plu_stats.rcv_data_bytes
- Number of normal flow data bytes received.
- ds_plu_stats.sidh
- Session ID high byte.
- ds_plu_stats.sidl
- Session ID low byte.
- ds_plu_stats.odai
- Origin destination address indicator. When bringing up a session, the sender of the BIND sets this field to zero if the local node contains the primary link station, and sets it to 1 if the BIND sender is the node containing the secondary link station.
- ds_plu_stats.ls_name
- Link station name associated with statistics. This is an 8-byte string in a locally displayable character set. All 8 bytes are significant.
- ds_plu_sscp_stats.pacing_type
- Receive pacing type in use on the downstream PLU-SLU session. This can be set to AP_NONE or AP_PACING_FIXED.
- us_plu_stats.rcv_ru_size
- Maximum receive RU size.
- us_plu_stats.send_ru_size
- Maximum send RU size.
- us_plu_stats.max_send_btu_size
- Maximum BTU size that can be sent.
- us_plu_stats.max_rcv_btu_size
- Maximum BTU size that can be received.
- us_plu_stats.max_send_pac_win
- Maximum size of the send pacing window on this session.
- us_plu_stats.cur_send_pac_win
- Current size of the send pacing window on this session
- us_plu_stats.max_rcv_pac_win
- Maximum size of the receive pacing window on this session.
- us_plu_stats.cur_rcv_pac_win
- Current size of the receive pacing window on this session.
- us_plu_stats.send_data_frames
- Number of normal flow data frames sent.
- us_plu_stats.send_fmd_data_frames
- Number of normal flow FMD data frames sent.
- us_plu_stats.send_data_bytes
- Number of normal flow data bytes sent.
- us_plu_stats.rcv_data_frames
- Number of normal flow data frames received.
- us_plu_stats.rcv_fmd_data_frames
- Number of normal flow FMD data frames received.
- us_plu_stats.rcv_data_bytes
- Number of normal flow data bytes received.
- us_plu_stats.sidh
- Session ID high byte. This field is reserved if dspu_services is set to AP_PU_CONCENTRATION.
- us_plu_stats.sidl
- Session ID low byte. This field is reserved if dspu_services is set to AP_PU_CONCENTRATION.
- us_plu_stats.odai
- Origin destination address indicator. When bringing up a session, the sender of the BIND sets this field to zero if the local node contains the primary link station, and sets it to 1 if the BIND sender is the node containing the secondary link station. This field is reserved if dspu_services is set to AP_PU_CONCENTRATION.
- us_plu_stats.ls_name
- Link station name associated with statistics. This is an 8-byte string in a locally displayable character set. All 8 bytes are significant. This field is reserved if dspu_services is set to AP_PU_CONCENTRATION.
- us_plu_stats.pacing_type
- Receive pacing type in use on the upstream PLU-SLU session. This can take the values AP_NONE or AP_PACING_FIXED.