DLUR_PU_INDICATION
This indication is generated whenever a DLUR PU is activated or deactivated. This allows a registered application to maintain a list of currently active DLUR PUs.
VCB Structure
typedef struct dlur_pu_indication
{
unsigned short opcode; /* verb operation code */
unsigned char reserv2; /* reserved */
unsigned char format; /* format */
unsigned short primary_rc; /* primary return code */
unsigned long secondary_rc; /* secondary return code */
unsigned char data_lost; /* previous indication lost */
unsigned char reason; /* reason for this indication */
unsigned char pu_name[8]; /* PU name */
unsigned char pu_id[4]; /* PU identifier */
unsigned char pu_location; /* downstream or local PU */
unsigned char pu_status; /* status of the PU */
unsigned char dlus_name[17]; /* current DLUS name */
unsigned char dlus_session_status; /* status of the DLUS pipe */
unsigned char reserv5[2]; /* reserved */
} DLUR_PU_INDICATION;Parameters
- opcode
- AP_DLUR_PU_INDICATION
- format
- Identifies the format of the VCB. This field is set to zero to specify the version of the VCB listed above.
- primary_rc
- AP_OK
- secondary_rc
- Equals zero.
- data_lost
- Specifies whether data has been lost (AP_YES or AP_NO). It is set when an internal component detects a failure that has caused a previous indication to be lost. If the data_lost flag is set to AP_YES then subsequent data fields can be set to null. The application should issue a QUERY verb to update the information that has been lost.
- reason
- The cause of the indication. It is one of the following:
- AP_ACTIVATION_STARTED
- The PU is activating.
- AP_ACTIVATING
- The PU has become active.
- AP_DEACTIVATING
- The PU has become inactive.
- AP_FAILED
- The PU has failed.
- AP_ACTIVATION_FAILED
- The PU has failed to activate.
- pu_name
- Name of the PU. This is an 8-byte alphanumeric type A EBCDIC string (starting with a letter), padded to the right with EBCDIC spaces.
- pu_id
- The PU identifier defined in a DEFINE_INTERNAL_PU verb or obtained in an XID from a downstream PU. This is a 4–byte hexadecimal string. Bits 0–11 are set to the block number and bits 12–31 are set to the ID number that uniquely identifies the PU.
- pu_location
- The location of the PU. This can be one of the following:
AP_INTERNAL
AP_DOWNSTREAM - pu_status
- The status of the PU (as seen by DLUR). This can be set to one of the
following:
- AP_RESET_NO_RETRY
- The PU is in reset state and will not be retried.
- AP_RESET_RETRY
- The PU is in reset state and be retried.
- AP_PEND_ACTPU
- The PU is waiting for an ACTPU from the host.
- AP_PEND_ACTPU_RSP
- After forwarding an ACTPU to the PU, DLUR is waiting for the PU to respond.
- AP_ACTIVE
- The PU is activate.
- AP_PEND_DACTPU_RSP
- After forwarding an DACTPU to the PU, DLUR is waiting for the PU to respond.
- AP_PEND_INOP
- DLUR is waiting for all necessary events to complete before it deactivates the PU.
- dlus_name
- The name of the DLUS node that the PU is currently using (or attempting to use). This is a 17–byte string composed of two type A EBCDIC character strings concatenated by an EBCDIC dot, that is right padded with EBCDIC spaces. (Each name can have a maximum length of 8 bytes with no embedded spaces.) If the PU activation has failed, this field will be set to all zeros.
- dlus_session_status
- The status of the DLUS pipe currently being used by the PU. This can
be one of the following:
AP_PENDING_ACTIVE
AP_ACTIVE
AP_PENDING_INACTIVE