TOT_LINK_ACT_LIM
![]() |
The TOT_LINK_ACT_LIM parameter keyword applies to Communications Server only. |
| Required? | No |
| Keyword Type | Unsigned number |
| Default | 255 |
| Range | 1–255 |
| Multiples Allowed? | No, only one for each PORT keyword |
TOT_LINK_ACT_LIM = (
@TYPE = UNSIGNEDNUMBERKEYWORD
@RANGE = 1,255
@DEFAULT = 255
)
The TOT_LINK_ACT_LIM parameter specifies the maximum number of link stations
that can be active concurrently. This must be greater than or equal to the
sum of the INB_LINK_ACT_LIM and OUT_LINK_ACT_LIM parameter values.
Note:
If the PORT_TYPE on the PORT keyword is specified as NONSWITCHED and the LINK_STATION_ROLE
on the PORT keyword is specified as NEGOTIABLE or SECONDARY, the TOT_LINK_ACT_LIM
parameter must be specified in the range greater than or equal to 1–255.
This parameter is optional.