POLL_TIMEOUT

Required? Yes
Keyword Type Unsigned number
Default 8000
The Communications Server icon
Default 3000
The Personal Communications icon
Range 500–10000
Multiples Allowed? No, only one for each PORT_LAN_SPECIFIC_DATA parameter
   POLL_TIMEOUT = (
      @TYPE = UNSIGNEDNUMBERKEYWORD
      @RANGE = 500,10000
      @REQUIRED = 1
      @DEFAULT = 8000
    )
 

The POLL_TIMEOUT parameter specifies the time that the LAN device waits for a response to a frame sent with the POLL bit set.

POLL_TIMEOUT is an integer in the range 500–10000 milliseconds.


The Communications Server icon
The default is 8000 milliseconds.

The Personal Communications icon
The default is 3000 milliseconds.

This parameter is required.