To select a CICS® system abend SVC dump or SYSMDUMP data set, first select the Analyze
MVS Dump Data Set option from the Fault Entry List display File menu (for information about selecting this option in
general, refer to Action-bar pull-down menus). This option brings up the Analyze MVS Dump Data Set display as
shown in Figure 1.
On this display, type the name of the SVC dump or SYSMDUMP data set containing the CICS®
system abend dump to be analyzed. The data set name-specification follows the ISPF data set name rules, that is, a data
set name that is not enclosed in single quotes is prefixed by the current TSO profile prefix. The data set specified is
checked for existence before being accepted. In this example, data set CICS.DUMP1 is being
analyzed.
The last data set name that is specified is stored in
the ISPF profile for your application ID and is used for initialization
of the display.
When the specified MVS™ dump data set name has been validated, the Fault AnalyzerCICS® system abend analysis