Verifying Fault Analyzer customization under CICS
This section is applicable only if you have CICS® installed, and have completed the customization of CICS® as described in Customizing the CICS environment.
Fault Analyzer IVP Testing Options: S=Select IVP Description _ 0C1 in program IDIXFA _ EXEC CICS DUMP DUMPCODE(FAD1) - XDUREQ exit must be installed _ EXEC CICS ABEND ABCODE(FLT1) _ EXEC CICS ABEND ABCODE(FLT2) - LE Assembler Use S to Select the IVP to execute PF3=Exit ENTER=Execute
From here, type S next to the desired tests (note that the XDUREQ exit must be installed for the EXEC CICS® DUMP DUMPCODE(FAD1) test), and press Enter.
Since DeferredReport is the default option for CICS®, determine the history file name and fault ID for each IVP from the IDI0003I messages, and then, using the Fault Analyzer ISPF interface, issue the 'V' line command against each fault entry to view the saved report.