Creating the MVS™ log streams

During CICS® VR VSAM batch logging, CICS® VR only attempts to connect and write to the appropriate log streams. CICS® VR does not attempt to create the log streams if they do not already exist. MVS™ log streams can be created by invoking the IXCMIAPU utility.

This defines the log stream to the MVS™ system logger, therefore allowing CICS® VR to connect to it. An example of using IXCMIAPU to define an undo log stream named DWW.UNDOLOG. See the MVS™ Setting up a Sysplex manual for more information about defining log streams:

Figure 1. Example using the IXCMIAPU utility to create a log stream
//*-------------------------------------------------------------------*/ 
//* Allocate UNDO LOG STREAM DWW.UNDOLOG                             */ 
//*-------------------------------------------------------------------*/ 
//DEFLGSTR EXEC PGM=IXCMIAPU                                             
//SYSPRINT DD   SYSOUT=*,DCB=RECFM=FBA                                   
//SYSIN    DD   *                                                        
   DATA TYPE(LOGR) REPORT(NO)                                            
     DEFINE LOGSTREAM NAME(DWW.UNDOLOG)                                  
            STRUCTNAME(LOG_GENERAL_001) LS_SIZE(1180)                    
            HIGHOFFLOAD(80) LOWOFFLOAD(40)                               
            AUTODELETE(NO) RETPD(0)                                      
            DESCRIPTION(CICSVR_UNOD_LOG)                                
/*