Creating the MVS™ log streams
During CICS® VR VSAM batch logging, CICS® VR only attempts to connect and write to the appropriate log streams. CICS® VR does not attempt to create the log streams if they do not already exist. MVS™ log streams can be created by invoking the IXCMIAPU utility.
This defines the log stream to the MVS™ system logger, therefore allowing CICS® VR to connect to it. An example of using IXCMIAPU to define an undo log stream named DWW.UNDOLOG. See the MVS™ Setting up a Sysplex manual for more information about defining log streams:
//*-------------------------------------------------------------------*/
//* Allocate UNDO LOG STREAM DWW.UNDOLOG */
//*-------------------------------------------------------------------*/
//DEFLGSTR EXEC PGM=IXCMIAPU
//SYSPRINT DD SYSOUT=*,DCB=RECFM=FBA
//SYSIN DD *
DATA TYPE(LOGR) REPORT(NO)
DEFINE LOGSTREAM NAME(DWW.UNDOLOG)
STRUCTNAME(LOG_GENERAL_001) LS_SIZE(1180)
HIGHOFFLOAD(80) LOWOFFLOAD(40)
AUTODELETE(NO) RETPD(0)
DESCRIPTION(CICSVR_UNOD_LOG)
/*