Changing global options
Use the Global Options Menu panel to modify the Collector global options.
3 Configure Global Options from the Collector Main
Administration Menu panel, CIU000 (shown in Collector Main
Administration Menu panel, CIU000). The Collector Global
Options Menu panel, Collector Global
Options Menu panel, CIU300,
is displayed. From this panel, you can set or modify the following
global options that apply to all the regions being monitored: - Whether VSAM file sharing is to be used
- Whether the CICS® IA collector is terminated when a CICS® IAerror occurs
- Whether high-level tracing is on or off
- Whether CICS® TS tracing is on or off
- The National Language to be used in screens and messages
- The date and time formats to be used in screens and messages
CIU300 CICS Interdependency Analyzer for z/OS - V6R1M0 2023:12:17
Global Options Menu 12:29:36AM
Modify the options and press Enter to update, or press F12 to cancel.
Control options
VSAM file sharing . . . . . : Y (Yes/No) ❶
Terminate on Abend . . . . . : N (Yes/No) ❷
High Level Trace . . . . . . : N (1/2/3/No) ❸
Restore Trace flags. . . . . : N (Yes/No) ❹
National Language Option . . . : E Code: ENU ❺
Date and Time Formats ❻
Date . . . . . . 4 1. MMDDYY 2. DDMMYY Separator . . . . . . . . :
3. YYMMDD 4. YYYYMMDD
Time . . . . . . 1 1. 12 hrs 2. 24 hrs Separator . . . . . . . . :
CICS Sysid: 1621 CICS Applid: C62C1C01 TermID: 1037
F1=Help F2= F3=End F4= F5= F6=
F7= F8= F9= F10= F11= F12=Cancel❶ VSAM file sharing
This
option is used to specify whether the Collector is
to save the dependency and affinity data for all monitored CICS® regions to a single set of
VSAM files that you have shared between regions using either VSAM
RLS or function shipping, or to multiple separate, region-specific,
sets of files. Type Y or N. The
default is N (No), data will be saved in separate
sets of files.
To control the operation of multiple instances
of the Collector,
running on different regions, from a single CICS® terminal, set this option to Y.
❷ Terminate on Abend
This
option is used to specify whether the Collector is
terminated with an IUZT abend when an
error occurs when CICS® IA queries Db2®. Type Y or N.
❸High Level Trace
This option is used to specify whether
the high-level trace is to be turned on for the Collector. Type 1,
2, or 3 to specify which level of trace
points you want to collect, or type N to turn off
this option. The default is N (No), trace is turned
off.
- The points of level 1 are included in CICS® IA modules at the entry and exit of a module.
- The points of level 2 are included in CICS® IA modules in all other cases.
- The points of level 3 are included in GLUE or TRUE.
You can set this levels through the CINT transaction.
❹ Restore Trace flags
This option is used to specify whether to restore Trace
flags values after a CICS® IA stop.
Type Y or N. The default is N (No),
trace is turned off.
❺ National Language Option
- E
- US English.
- K
- Japanese. For Japanese to be displayed, the terminal must be configured with the CICS® SOSI attribute.
❻ Date and Time Formats
To set the date format to be used by CICS® IA, type
the corresponding number (1 - 4)
in the Date field. The default is 4.
Type the separator character to be used in dates (for example, / or – )
in the Date Separator field. The default character
is
. /
To set the time format to
be used by CICS® IA,
type the corresponding number (1 for 12-hour clock
format or 2 for 24-hour clock format) in the Time field. The times are shown in the
local time. The default is 1. Type the
separator character to be used in times in the Time Separator field. The
default character is
. :