Recovering from errors on a submit/release data set

About this task

If a submit/release data set has been damaged, follow this procedure:
  1. Stop any IBM® Z Workload Scheduler subsystem that is writing to or reading from the data set.
  2. Delete the submit/release data set, and allocate a new data set.
  3. Start IBM® Z Workload Scheduler again.
    Note: The first time IBM® Z Workload Scheduler is started with a newly allocated submit/release data set, an SD37 error occurs when IBM® Z Workload Scheduler formats the data set. Expect this; do not treat it as an error.
  4. Enter the Modify Current® Plan dialog, and check the status of operations in the current plan. Concentrate on computer workstations that are connected to the controller via the failing submit/release data set. If you determine that a job submission action has been missed, reset the operation to READY status.