Viewing results in Rational® Test Control Panel
You can use IBM® Rational® Test Control Panel to display the results of tests that you run in both Rational® Integration Tester and Rational® Test Control Panel.
Procedure
-
Make sure that
Rational® Test Control
Panel is
configured to use the database driver that corresponds to the results database whose
contents you want to display. To use a database driver, copy the .jar
file to the following folder:
RTCP_installation_directory\usr\servers\defaultServer\apps\RTCP.war\WEB-INF\lib
-
On the Results page of the user interface for
Rational® Test Control
Panel, locate the
Database field. In the Database field,
select the database to be displayed.
To add a database to the list, two methods are available:
- In
Rational® Integration
Tester, complete the
following steps:
- From the top menu, click .
- Click the Server Settings tab.
- In the Rational Test Control Panel section, click Publish results database connection.
- Refresh the Results page in the browser.
- In
Rational® Test Control
Panel, complete the
following steps:
- In the top menu, click Administration.
- Click the Results databases tab.
- Click New.
- In the Enter new database details window, enter a name for the database. This field has no label. If you leave the field blank, a descriptive name is created for you.
- In the Type field, select the type of the database:.
- A template for the JDBC URL, which is based on database type, is displayed in the Database URL field. Edit this field to match the value for your database. For more information on the specification of database URLs when using IP literal addresses, see IP literal address.
- If credentials are required to access the database, complete the Username and Password fields.
- Click Test Connection to verify the information that you entered. If an error message is displayed, review the contents of the Database URL field.
- When the information is correct, click Save.
- Return to the Results page. The new database entry is now listed in the Database field.
- In
Rational® Integration
Tester, complete the
following steps:
-
Use the Type field to filter results by the following types of
results:
- Tests
- Results that are generated by single tests.
- Suites
- Results that are generated by test suites.
- Stubs
- Results that are generated by stubs.
- Test cycles
- Results that are generated by full test cycles.
-
Use the Name field to filter results according to the name of
the test, suite, stub, or cycle.
Partial names are recognized, and a percent sign (%) can be used as a wildcard to match any number of characters. Contents of the field are not case sensitive. If you have a test suite named "DataTestSuite", then "data", "Test", or "Data%Suite" finds the results for the suite. Leave this field empty to retrieve all results.
- Use the From and To fields to provide a date range for the displayed results.
-
Click Search to display the requested results.
Note: The Domain field is not relevant to the Results page.
-
To view more detailed results, click the link in the Start time
column for any displayed result.
A new page is displayed that contains execution records for the selected test, suite, stub, or cycle.
What to do next
To return to a particular set of results, you can bookmark or share the URL in the
address line of your browser at any of the following points:
- After you complete a search
- After you select a test, suite, stub, or cycle
- After you open the execution records page
- After you select an execution record