Troubleshooting: TIBCO
You can use workarounds to common problems that you might encounter when you are testing TIBCO products in Rational® Integration Tester.
Problem | Description | Solution |
---|---|---|
No formatter available | If the Formatter combination list is blank in a message editor, it is likely that the requisite JAR files were not included on the classpath when Rational® Integration Tester started. | The Library Manager must be configured and enabled for the TIBCO AE provider. |
Unable to connect to daemon | This can occur when either the application is unable to start a suitable local daemon process or if the daemon settings in the transport configuration are invalid/reference an unreachable remote transport. | In these cases, check that the directory in which the rvd file is present is on the system PATH environment variable. |
Overlapping subjects error |
When you are using an RVCM-based transport, there are restrictions to the subjects to which you can subscribe at any point. For example, it is not possible to have two tests that use the same RVCM transport with subscriptions to the subjects 'test.>' and 'test.application'. Which would result in an error as you could potentially have two subscribers to the same subject and Rendezvous would not know how to handle the certified acknowledgements. |
|
Class definitions not visible |
Changes that are made to the schema definitions inside of TIBCO Designer are not visible in Rational® Integration Tester until you synchronize the artifacts again. Which is done in the Synchronize view of Architecture School. |
|
AE transport unable to use BusinessWorks 5 projects |
BusinessWorks 5 uses TIBCO AE version 5 libraries. You must run Rational® Integration Tester with AE5 JAR files (v4 do not work). These settings can be confirmed in the Library Manager. |
|
Unable to watch EMS queues |
Ensure that the transport connects with administration permissions as watching
involves accessing system topics instead of the target queues. You also need to clear the
|
|
Unable to access topics or queues on remote servers |
This error is normally due to the a problem with connection factory configuration. When you make a remote connection to an EMS server, the initial connection to the connection factory returns the location of the queue or topic. If the connection factory is configured incorrectly for a default port number or localhost, it informs Rational® Integration Tester to connect to its local machine or use the wrong port number. |
Refer to the TIBCO EMS documentation and check the connection factory settings
by using the TIBCO tool tibemsadmin. An example follows where the connection factory has a correct
URL (that is, no host
name):
|
Not permitted error when you are watching |
If the admin credentials are edited after an action is performed by using the EMS transport, Rational® Integration Tester will need to be restarted to fully apply the changes. |
|
Unable to tag generated tracking ID |
When publishing messages by using the AE transport, the TIBCO APIs adds a tracking ID. Store actions within a publisher are currently unable to process this value. |
|
Failed to rebuild schema | If transports are created on the Windows™ system and used on a Unix-like system, the path separators can prevent the transports schema from being able to refresh. |
In this case, the reference to the DAT file needs to be updated within the Unix-like environment. |
Unable to start recording the EMS messages with the following error:
Failed to Monitor EMS messages with user_name not permitted . |
To record EMS messages without removing them from the server,
Rational® Integration
Tester subscribes
to the system topics. To access these topics, special permissions are required. If the EMS transport is not using an administrator user ID, you might not have the necessary permissions. |
|