SERVICE ... END SERVICE
Appies to C Test Script Language
Syntax
SERVICE <service_name>
END SERVICE
Description
The SERVICE instruction starts a SERVICE block. This block contains the description of all the tests relating to a given service of the module to be tested.
The <service_name> parameter flags the tested service in the test report, and is therefore usually the name of this service (although this is not obligatory).
The END SERVICE instruction indicates the end of the service block.
Associated Rules
The SERVICE instruction must appear after the BEGIN instruction.
The <service_name> parameter can be any identifier. It is obligatory. It must be unique in the PTU.
Example
BEGIN
SERVICE COMPUTE_HISTO
# int x1, x2, y1, y2 ;
# int status ;
# T_HISTO histo;
TEST 1
FAMILY nominal