iSeries, eServer i5, or System i5 Device Description for Twinaxial Attachments (APPC) Example

If you want to use a twinaxial (TDLC) attachment, the iSeries, eServer i5, or System i5 requires that you specify a device description. When the automatic device configuration indicator (QAUTOCFG) is set to ON in the iSeries, eServer i5, or System i5, the device description is created automatically. When the indicator is set to OFF, create the device description, as follows:
  1. Enter the following command on the command line of the iSeries, eServer i5, or System i5 main menu:
      CRTDEVDSP
    The Creating Device Description (Display) panel appears.
                     Creating Device Description(Display)   (CRTDEVDSP)
     
    Type the selected item, and push Enter key.
     
    Device Description...    Name
    Device Class..........            *LCL, *RMT, *VRT, *SNPT
    Device Type...........            3101, 3151, 3161, 3162...
    Device Format........             0, 1, 2, 4, 11, 12, 23...
     
     
     
     
     
     
     
     
     
     
     
                                                                              End
     F3=Exit    F4=Prompt         F5=Reshow    F10=Add parameter   F12= Cancel
     F13=How to use this panel                 F24=More key
     
  2. Type the values in each field, according to the following table.
    Field Name Input Value
    Device description This is an optional field
    Device class *LCL
    Device type 5150
    Device format 2
  3. After you type all values, press the Enter key.
    The following screen appears:
                     Creating Device Description(Display)   (CRTDEVDSP)
     
    Type the selected item, and push Enter key.
     
    Device Description..........>TWXP0A1 Name
    Device Class................>*LCL       *LCL, *RMT, *VRT, *SNPT
    Device Type.................>5150       3101, 3151, 3161, 3162...
    Device Format...............>2       0, 1, 2, 4, 11, 12, 23...
    Port Number.................             0-17
    Switch Setting..............             0, 1, 2, 4, 5, 6
    Online when IPL.............>*YES       *YES,  *NO
    Controller to be attached...       Name
    Keyboard Word Type..........>*SYSVAL     *SYSVAL,AGB,AGI,BLI...
    Text Description............>*BLANK
     
     
     
     
     
     
    F3=Exit    F4=Prompt         F5=Reshow    F10=Add parameter   F12= Cancel
    F13=How to use this panel                 F24=More key
     
  4. Type the values for each field, according to the following table.

    Field Name Input Value
    Port number Number of the port to be attached
    Switch setting Device address
    Controller to be attached Descriptive name of the controller to be attached
    Keyboard word type USB1
    1 Depends on the host code page selection.
  5. After you enter all the values, press the Enter key.

    This completes the creation of the device description for the twinaxial attachment.