Fault history file selection

When a fault is being analyzed in real time by Fault Analyzer, a history file must be available in which details of the analysis can be recorded.

There are a number of ways in which the name of the history file can be provided to Fault Analyzer. The following is a list of these in the order of their override significance (each entry in the list overrides all previous entries):

  1. The product default name, IDI.HIST.
  2. The IDIHIST suboption of a DataSets option that is specified in the parmlib config member, IDICNF00. This information includes either the logical parmlib concatenation or the installation-wide alternate parmlib data set name provided via the IDIOPTLM configuration-options module IDICNF setting. For details, see Customize Fault Analyzer by using an IDIOPTLM configuration-options module.
  3. The IDIHIST suboption of a DataSets option that is specified in a config member identified via the IDICNFUM user options module.
    Note: If a user options module is used, it replaces the default IDICNF00 parmlib config member. Thus, even if the user options module designated config member did not include an IDIHIST suboption of a DataSets option, any specification of IDIHIST in the default IDICNF00 parmlib config member would not be recognized.
  4. The IDIHIST suboption of a DataSets option provided via the IDIOPTS DDname in the abending job step.
  5. An explicitly coded IDIHIST DD statement in the abending job step.
  6. The data set name provided by an Analysis Control or End Processing user exit in the ENV data area IDIHIST field.