Configuring Rational® Integration Tester

You must configure Rational® Integration Tester to work with TIBCO Business Works.

About this task

In the Physical View of Architecture School, do the following steps:

Procedure

  1. Ensure that you added a TRA file (properties.cfg from TIBCO Designer or a BW TRA file). You can add a TRA file when you import the BW project, but you can add one later as well.
  2. In the Logical View of Architecture School, set the binding per environment to the required TRA by right-clicking as shown.
  3. Confirm that the RV trace messages can be received by Rational® Integration Tester. Rational® Integration Tester TRA file must be configured with the same tracing parameters in order for it to be able to generate full BW test reports. In most instances, Rational® Integration Tester is running on a different server from BW and you must ensure that the RV trace messages can be received by Rational® Integration Tester. If the two machines are not on the same broadcast or multicast network, it is necessary to configure the Rational® Integration Tester RV daemon parameter to connect to the remote RVD. You would need a setting for each type of trace message (Info/Warn/Error/Debug) but a single example follows:
    Trace.Debug.Publish.Daemon=tcp:remoteserver:7575