Configuring the webMethods Broker probe

How to configure the webMethods Broker probe.

About this task

The webMethods Broker probe runs on a webMethods Broker that is configured in the Architecture School Physical View.

To configure the default probe or add another:

Procedure

  1. Edit the broker and click the Probes tab.
  2. Next, you can choose from one of the following actions:
    • To add a new probe, click Add > webMethods Broker.
    • To copy an existing probe, select the probe and click Copy.
    • To delete a probe, select the probe and click Remove.
  3. For probes other than the default one, you can enter a name in the Name field.
  4. In the Collect statistics every... field, enter the frequency at which statistics are to be collected.
  5. Under the Event Types, Clients, and Client Groups tabs you can add specific counters for which data can be collected (for more information, refer to webMethods Broker probe).
  6. To add an entry under the selected tab, click Add and enter the counter name when prompted.
  7. To modify the name of an existing counter under the current tab, select it and click Edit.
  8. To delete a counter from the current tab, select it and click Delete.
  9. To clear the current selection, click Clear.