SERVICE ... END SERVICE
Ada Test Script Language
Purpose
A SERVICE block contains a common description for all tests related to a given service of the module under test.
Syntax
SERVICE <service_name>
END SERVICE
where:
-
<service_name> specified the tested service in the test report
Description
The SERVICE instruction starts a SERVICE block. This block contains the description of all the tests relating to a given service of the module to be tested.
The <service_name> is usually the name of thes service under test, although this is not mandatory.
The END SERVICE instruction indicates the end of the service block.
Associated Rules
The SERVICE instruction must appear after the BEGIN instruction.
The <service_name> parameter can be any identifier. It is obligatory.
Example
BEGIN
SERVICE COMPUTE_HISTO
# x1, x2, y1, y2 : integer ;
# histo : T_HISTO ;
TEST 1
FAMILY nominal